Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, redce rework and reject rate, reduce cleaning costs
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Compression Tehnology
Time Required
15-30 minutes
Segment
Substrate
Machine Manufacturing
Stainless Steel
Steel
Soil
Cutting Fluids Grease Oil, Shop Dirt
Description of Part(s)
Description of Part
Disks
Cleaner Used
55 by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in an Ultrasonic Washer for a minimum of 60+ minutes