Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, redce rework and reject rate, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Compression Tehnology
15-30 minutes
Segment
Substrate
Machine Manufacturing
Stainless Steel, Steel
Soil
Cutting Fluids, Grease, Oil, Shop Dirt
Description of Part(s)
Disks
Cleaner Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in an Ultrasonic Washer for a minimum of 60+ minutes