Skip to main content
Before
After

Cleaning Trial Summary

Segment
:: TSR #19-A-112

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce rework and reject rate, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Remanufacturing
Time Required
15 minutes in Spray Washer, followed by 15 minutes in Spray Under Immersion Washer
Segment
Substrate
Dealership
Iron Steel
Soil
, Baked on Carbon
Description of Part(s)
Description of Part
Mid-sized gear
Cleaner Used
Machine Used
Machine Used

Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3) followed by Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume of ArmaKleen™ M-100 BCR at 160°F in a Spray Under Immersion Washer for a minimum of 30 minutes