Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce rework and reject rate, reduce cleaning costs
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Remanufacturing
Time Required
15 minutes in Spray Washer, followed by 15 minutes in Spray Under Immersion Washer
Segment
Substrate
Dealership
Iron
Steel
Soil
, Baked on Carbon
Description of Part(s)
Description of Part
Mid-sized gear
Cleaner Used
10% by volume M-100 BCR (Baked on Carbon Remover)
Machine Used
Machine Used
Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3) followed by Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume of ArmaKleen™ M-100 BCR at 160°F in a Spray Under Immersion Washer for a minimum of 30 minutes