Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce rework and reject rate
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Tool Manufacturing
Time Required
30 minutes
Segment
Substrate
Machine Manufacturing
Iron
Stainless Steel
Steel
Soil
Cutting Fluids, Oil
Description of Part(s)
Description of Part
Assortment of small gears
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 30 minutes