

Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce rework and reject rate, clean mixed metals together, reduce cleaning costs, utilize one cleaner for all types of metals
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Machine Manufacturing
Time Required
15-30 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum
Copper/brass
Iron
Stainless Steel
Steel
Soil
Cutting Fluids, Oil
Description of Part(s)
Description of Part
Assortment of screws, nuts, bolts
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
- Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
- Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ BIO-24 at 160°F in a Spray Under Immersion Washer for a minimum of 15 to 30 minutes or a 5% by volume solution of ArmaKleen™ BIO-24 at 160°F in an Ultrasonic Washer for a minimum of 15 to 30 minutes