Improve cleaning performance, automate cleaning process, reduce cleaning costs

Cleaning Trial Type
Temperature
Coating
150°F
Industry
Time Required
Marine
3 hours
Segment
Substrate
Transportation Equipment Manufacturing
Copper-nickel
Soil
Adhesive, Glue, Oil, Rust/Oxides, Salt buildup cooked descale
Description of Part(s)
Heat exchanger
Cleaner Used
Machine Used

Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume of ArmaKleen™ Rust Remover at 150°F in a Spray Under Immersion Washer for a minimum of 3 hours