Cleaning Trial Summary
Customer Objective
Improve cleaning performance
Cleaning Trial Type
Temperature
Polymer
Temperature
160°F
Industry
Time Required
Industry
Sharpening Services
Time Required
90 minutes
Segment
Substrate
Auto Maintenance
Steel
Soil
Fiberglass, Plastic
Description of Part(s)
Description of Part
Saw blades
Cleaner Used
100% by volume ARMAKLEEN™ Paint & Ink Remover
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ Bio24 at 160°F in an Ultrasonic Washer for a minimum of 90 minutes