Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #19-A-091

 

Customer Objective

Improve cleaning performance

Cleaning Trial Type
Temperature
Polymer
Temperature
160°F
Industry
Time Required
Industry
Sharpening Services
Time Required
90 minutes
Segment
Substrate
Auto Maintenance
Steel
Soil
Fiberglass, Plastic
Description of Part(s)
Description of Part
Saw blades
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ Bio24 at 160°F in an Ultrasonic Washer for a minimum of 90 minutes