Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #19-A-082

 

Customer Objective

Automate cleaning process, reduce cleaning costs, eliminate hazardous chemicals/waste, eliminate immersion washer

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Packaging and Handling
Time Required
1 hour
Segment
Substrate
Non-metal Manufacturing
Copper/brass Iron Steel
Soil
Grime, Oil
Description of Part(s)
Description of Part
Small and medium fittings and parts
Cleaner Used
Machine Used
Machine Used

Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™Bio24 at 160°F in a Spray Under Immersion Washer for a minimum of 1 hour