Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #19-A-080

 

Customer Objective

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Pump Manufacturing
Time Required
15 minutes
Segment
Substrate
Machine Manufacturing
Iron Steel
Soil
Oil Rust/Oxides, Shop Dirt
Description of Part(s)
Description of Part
Pump parts
Cleaner Used
Machine Used
Machine Used

Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

 ArmaKleen Technical Center recommends using a 5% by volume of ArmaKleen™ Bio 24 at 160°F in a Spray Washer for a minimum of 15 minutes