Cleaning Trial Summary
Customer Objective
Improve cleaning performance
Cleaning Trial Type
Temperature
Aqueous
Temperature
120°F, 150°F
Industry
Time Required
Industry
Automotive
Time Required
15 minutes
Segment
Substrate
Transportation Equipment Manufacturing
Steel
Soil
, Oil
Description of Part(s)
Description of Part
Manufactured bolts
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Agitating Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried, followed by parts being placed in an incubator at 212°F
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio24 at 150°F in an Agitating Immersion Washer (model 81.8) for a minimum of 15 minutes