Cleaning Trial Summary
Customer Objective
Automate cleaning process and have cleaned/dried parts be rust-free
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Metal-working
Time Required
15 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum
Steel
Soil
, Vibratory residue
Description of Part(s)
Description of Part
Ductile iron machined cast dies
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried, followed by parts being placed in an incubator at 220°F
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Under Immersion Washer for a minimum of 15 minutes