Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate

Cleaning Trial Type
Temperature
Aqueous
150°F
Industry
Time Required
Watch Parts Manufacturing
15 minutes-2 hours
Segment
Substrate
Non-metal Manufacturing
Stainless Steel, Steel
Soil
Grease, Grime, Oil
Description of Part(s)
Assortment of cylinders, disks, rings
Cleaner Used
Machine Used

Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 15 minutes to 2 hours