Cleaning Trial Summary

:: TSR #19-A-005

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce rework and reject rate

Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Watch Parts Manufacturing
Time Required
15 minutes-2 hours
Segment
Substrate
Non-metal Manufacturing
Stainless Steel Steel
Soil
Grease Grime, Oil
Description of Part(s)
Description of Part
Assortment of cylinders, disks, rings
Cleaner Used
Machine Used
Machine Used

Spray Under Immersion (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 150°F in a Spray-Under Immersion Washer for a minimum of 15 minutes to 2 hours