Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #18-P-181

 

Customer Objective

Improve cleaning performance and reduce rework and reject rate

Cleaning Trial Type
Temperature
Paint
Temperature
160°F, 150°F
Industry
Time Required
Industry
Pump Manufacturing
Time Required
2 hours
Segment
Substrate
Machine Manufacturing
Steel
Soil
, Acrylic paint
Description of Part(s)
Description of Part
Paint hooks
Cleaner Used
Machine Used
Machine Used
  • Ultrasonic Washer (SK Blackstone 6315)
  • Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 2 hours or at 150°F in a Spray-Under Immersion Washer for a minimum of 2 hours