Cleaning Trial Summary
Customer Objective
Improve cleaning performance
Cleaning Trial Type
Temperature
Polymer
Temperature
160°F
Industry
Time Required
Industry
Automotive
Time Required
4-16 hours
Segment
Substrate
Auto Maintenance
Brass
Soil
, Sand/resin
Description of Part(s)
Description of Part
Filters
Cleaner Used
100% by volume ARMAKLEEN™ Paint & Ink Remover
Machine Used
Machine Used
Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 4-16 hours