Cleaning Trial Summary
Customer Objective
Improve cleaning performance, reduce rework and reject rate, reduce VOCs, recover scrap parts
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Performance Products Manufacturing
Time Required
15-30 minutes
Segment
Substrate
Miscellaneous Manufacturing
Aluminum
Soil
, Oil
Description of Part(s)
Description of Part
Piston heads
Cleaner Used
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure drying
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Under Immersion Washer for a minimum of 15-30 minutes