Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #18-A-065

 

Customer Objective

Improve cleaning performance, clean mixed metals together

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Steel and Mining
Time Required
30 minutes to 1 hour
Segment
Substrate
Civil/Heavy Construction
Glass Plastic Steel
Soil
Grime, Shop Dirt
Description of Part(s)
Description of Part
Lens cover, plastic cover, and clip
Cleaner Used
Machine Used
Machine Used

Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Under Immersion Washer for a minimum of 1 hour