Cleaning Trial Summary
Customer Objective
Improve cleaning performance, automate cleaning process, reduce VOCs
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Machined Parts Manufacturing
Time Required
15-30 minutes
Segment
Substrate
Machine Manufacturing
Aluminum
Stainless Steel
Soil
Bending lube Cutting Fluids Grime, Oil
Description of Part(s)
Description of Part
Pipes
Cleaner Used
10% by volume M-100 BCR (Baked on Carbon Remover)
5% by volume ArmaKleen™ Bio 24
Machine Used
Machine Used
Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/ SUI)
Post Cleaning
Post Cleaning
Fresh water rinse and air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-100 BCR at 160°F in a Spray-Under Immersion Washer or a 5% by volume solution of ArmaKleen™ Bio 24 at 160°F in a Spray-Immersion Washer for a minimum of 15-30 minutes