Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #18-A-024

 

Customer Objective

Improve cleaning performance and automate cleaning process

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Metalworking
Time Required
1 hour
Segment
Substrate
Fabricated Metal Product
K500 Monel QQN-281 Stainless Steel
Soil
Cutting Fluids Grease, Molykote P37
Description of Part(s)
Description of Part
Process machine components
Cleaner Used

10% by volume ARMAKLEEN™ M-HP-2

Machine Used
Machine Used
  • Ultrasonic Washer (SK Blackstone 6315)
  • Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
Post Cleaning
Post Cleaning

Some parts were rinsed with fresh water and air pressure dried, while other parts were only air pressure dried

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-HP-2 at 160°F in an Ultrasonic Washer for a minimum of 1 hour or a 10% by volume solution of ArmaKleen™ M-HP-2 at 160°F in a Spray Washer for a minimum of 1 hour, both with a fresh water rinse