Customer Objective

The customer was looking to improve their cleaning performance, automate their cleaning process and reduce rework and reject rate.

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Transmission remanufacturing
Time Required
4-8+ hours
Segment
Substrate
Auto Maintenance
Plastic Rubber Stainless Steel
Soil
, Oil
Description of Part(s)
Description of Part
an assortment of stainless steel conductors with plastic connectors and rubber gaskets
Cleaner Used
Machine Used
Machine Used

Ultrasonic Washer (SK Blackstone model 6315)

Post Cleaning
Post Cleaning

Fresh rinse followed by air pressure drying.

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-100 BCR at 160°F in an Ultrasonic Washer  or a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 160°F in an Ultrasonic Washer for a minimum of 4-8+ hours.