Skip to main content
Before
After

Cleaning Trial Summary

:: TSR #17-A-214

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce rework and reject rate, clean mixed metals together, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Tool Repair
Time Required
30 minutes
Segment
Substrate
Fabricated Metal Product
Aluminum Nickel Alloys Stainless Steel
Soil
Cutting Fluids Oil, Shop Dirt
Description of Part(s)
Description of Part
Assortment of machine brackets/braces, connectors
Cleaner Used

10% by volume ARMAKLEEN™ M-Aero

Machine Used
Machine Used

Spray Under Immersion (SK Model 81.8, Graymills T12, Graymills T24 w/ SUI)

Post Cleaning
Post Cleaning

Fresh water rinse and air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-Aero at 160°F in a Spray-Under Immersion Washer for a minimum of 15-30 minutes