Cleaning Trial Summary

:: TSR #17-A-195

 

Customer Objective

Improve cleaning performance, automate cleaning process, reduce rework/reject rate

Cleaning Trial Type
Temperature
Rust
Temperature
160°F
Industry
Time Required
Industry
Glass manufacturing
Time Required
2 hours
Segment
Substrate
Building Material
Stainless Steel
Soil
, Rust/Oxides
Description of Part(s)
Description of Part
Glass vial molds
Cleaner Used
Machine Used
Machine Used

Ultrasonic (SK Blackstone 6315)

Post Cleaning
Post Cleaning

Fesh water rinse and air pressure drying

Recommendation to Customer
Recommendation

The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ Rust Remover at 160°F in an Ultrasonic Washer for a minimum of 30 minutes to 2 hours