Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, reduce rework and reject rate and reduce their cleaning costs.
Cleaning Trial Type
Temperature
Epoxy paint
Temperature
150°F – 160°F
Industry
Time Required
Industry
Material handling equipment supplier
Time Required
24 hours
Segment
Substrate
Machine Manufacturing
Steel
Soil
, Liquid epoxy paint
Description of Part(s)
Description of Part
a steel hook and chain set, a triangular steel brace and a steel bolt
Cleaner Used
100% by volume ARMAKLEEN™ Paint & Ink Remover
Machine Used
Machine Used
· Agitated Immersion Spray Washer (SK Model 81.8, Graymills T24)
· Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 100% by volume solution of ArmaKleen™ Paint and Ink Remover at 150°F in an Agitating Immersion Washer for a minimum of 24+ hours.