Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance and automate their cleaning process.
Cleaning Trial Type
Temperature
Aqueous
Temperature
160°F
Industry
Time Required
Industry
Security and Surveillance Tech
Time Required
4 – 8 minutes
Segment
Substrate
Miscellaneous Manufacturing
Aluminum
Soil
, Cutting Fluids
Description of Part(s)
Description of Part
Four aluminum electrical boxes/frames
Cleaner Used
10% by volume ARMAKLEEN™ MM-Recycle
Machine Used
Machine Used
Spray Under Immersion Washer (Graymills T12, Graymills T24, SK Model 81.8 w/SUI)
Post Cleaning
Post Cleaning
Air pressure dried
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ MM-Recycle at 160°F in a Spray-Under Immersion Washer for a minimum of 4 minutes to 8 minutes.