Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and eliminate hazardous/waste.
Cleaning Trial Type
Temperature
Aqueous
Temperature
120°F
Industry
Time Required
Industry
Production of Hydraulic components
Time Required
1 hour
Segment
Substrate
Fabricated Metal Product
Aluminum
Plastic
Stainless Steel
Steel
Soil
Grime Oil, Shop Dirt
Description of Part(s)
Description of Part
A connector
Cleaner Used
10% by volume ARMAKLEEN™ M-HP-2
Machine Used
Machine Used
Spray Washer (JRI TL3, JRI FL250, JRI FL500, Better Engineering G-2000)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommends using a 10% by volume solution of ArmaKleen™ M-HP-2 at 120°F in a Spray Washer for a minimum of 1+ hours.