Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance, automate their cleaning process and reduce rework and reject rate.
Cleaning Trial Type
Temperature
Aqueous
Temperature
150°F
Industry
Time Required
Industry
Diesel Repair
Time Required
2 to 4 hours
Segment
Substrate
Dealership
Steel
Soil
Grease, Rust
Description of Part(s)
Description of Part
Frames
Cleaner Used
10% by volume ARMAKLEEN™ Rust Remover
Machine Used
Machine Used
Agitating Immersion Washer (SK 81.8, Graymills T12, Graymills T24)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ Rust Remover at 150°F in an Agitating Immersion Washer for a minimum of 2 to 4 hours.