Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance and reduce their cleaning costs.
Cleaning Trial Type
Temperature
Aqueous
Temperature
150 – 160°F
Industry
Time Required
Industry
OEM Manufacturing
Time Required
5 to 8 hours
Segment
Substrate
Machine Manufacturing
Plastic
Rubber
Steel
Soil
Grease Hard water scale build-up Oil, Soap scale
Description of Part(s)
Description of Part
Spray paint nozzles
Cleaner Used
10% by volume ARMAKLEEN™ Rust Remover
Machine Used
Machine Used
- Agitating Immersion Washer (SK 81.8, Graymills T12, Graymills T24)
- Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning
Post Cleaning
Fresh water rinse followed by air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ Rust Remover at 160°F in an Ultrasonic Washer for a minimum of 5 hours.