Cleaning Trial Summary
Customer Objective
The customer was looking to improve their cleaning performance.
Cleaning Trial Type
Temperature
Aqueous Calcium
Temperature
160⁰F
Industry
Time Required
Industry
Manufacturing
Time Required
2 hours
Segment
Substrate
Chemical Manufacturing
Stainless Steel
Soil
Calcium Build Up, Paint Pigment
Description of Part(s)
Description of Part
Stainless steel mesh and post
Cleaner Used
10% by volume ARMAKLEEN™ Rust Remover
Machine Used
Machine Used
Ultrasonic Washer (SK6315 Blackstone model 3523)
Post Cleaning
Post Cleaning
Fresh water rinse with air pressure drying.
Recommendation to Customer
Recommendation
The ArmaKleen Technical Center recommended using 10% by volume ArmaKleen™ Rust Remover at 160⁰F in an Ultrasonic Washer for a minimum of 2 hours for cleaning the mesh and a Spray Under Immersion Washer for a minimum of two hours for cleaning the post.