Before
After

Cleaning Trial Summary

 

Improve cleaning performance, automate cleaning process, reduce rework and reject rate, reduce cleaning costs

Cleaning Trial Type
Temperature
Aqueous
160°F
Industry
Time Required
Aerospace
1 hour
Segment
Substrate
Transportation Equipment Manufacturing
Aluminum, Iron, Steel
Soil
Baked on Carbon, Grease, Grime, Oil
Description of Part(s)
Turbocharger components
Cleaner Used
Machine Used
  • Spray Washer (JRI FL 250, JRI FL 500, JRI TL 3)
  • Ultrasonic Washer (SK Blackstone 6315)
Post Cleaning

Fresh water rinse and air pressure dried

Recommendation to Customer

The ArmaKleen Technical Center recommends using a 10% by volume solution ArmaKleen™ M-100BCR at 160°F in an Ultrasonic Washer for a minimum of 1 hour